eLearning

Global

AquaMist - The Broadest Range of Water Mist Systems from Johnson Controls


This video provides an overview of each of our Water Mist fire-fighting systems, including AquaMist ULF, a low pressure system, AquaMist FOG, a high pressure Water Mist system and AquaMist SONIC, a hybrid technology.

Please use the below link to start the video on YouTube:
AquaMist - The Broadest Range of Water Mist Systems from Johnson Controls

Water Mist video logo

Live Training

APAC/ME

AquaMist for Building Protection


Certification Training for AquaMist low pressure systems for Building protecting
 

The objective of this certification training session is an introduction on the AquaMist ULF low pressure watermist technology as a Performance-based Design System for protection of Light and Ordinary Hazard (OH1) occupancies. A general overview on the fire tests done for the FM approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details. 

The course will end with an exam and attendees will receive a certificate of training. 


Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF for Light and Ordinary Hazards (OH1), design.
  • AquaMist System hardware.
  • Introduction to AquaMist ULF for Industrial Fryer Protection (FM approved systems)
  • Introduction to AquaMist ULF for Data Center Protection (FM approved systems)
  • Demonstration of low pressure water mist nozzle discharges (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe 
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist for Machinery Spaces


Certification Training for AquaMist systems for protecting Machinery Spaces
  

The objective of this certification training session is an introduction to the AquaMist ULF low pressure water mist technology for protection of Machinery Spaces according FM and IMO regulations, also AquaMist FOG high pressure cylinder based FM approved systems for protection of Machinery Spaces according FM will be covered. A general overview on the fire tests done for the FM/IMO approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details.

The course will end with an exam and attendees will receive a certificate of training.


Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF Machinery Spaces system design for total flooding systems according FM, local application acc. IMO.
  • AquaMist FOG Machinery Spaces system design for total flooding systems according FM.
  • AquaMist System Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe 
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist low pressure for Data Center


Certification Training on AquaMist ULF systems for protecting large Data Halls in Datacenters 
  

The objective of this certification training session is an introduction on the AquaMist ULF low pressure water mist technology for protecting large Data Halls with computer racks in Data Centers. A general overview on the fire tests done for the FM approved system, nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details.

The course will end with an exam and attendees will receive a certificate of training.


Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF for Data Center protection, system design.
  • AquaMist ULF System hardware.
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe 
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist low pressure for Industrial Fryers


Certification Training for AquaMist ULF systems for protecting Industrial Fryers
  

The objective of this certification training session is an introduction on the AquaMist ULF low pressure water mist technology for protecting large Industrial Fryers in the food industry. A general overview on the fire tests done for the FM approved system, nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details. 

The course will end with an exam and attendees will receive a certificate of training.


Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF IFP for Industrial Fryer protection, system design.
  • AquaMist ULF System hardware.
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe 
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist Low-pressure Solutions


Introduction training to AquaMist low pressure water mist solutions
   

The objective of this Introduction training session on AquaMist Solutions is to explain the control/suppression/extinguishing principles of low pressure water mist systems and broad range of different applications where to use low pressure water mist systems based on fire protection standards as NFPA750 and CENTS14972.

After attending this one day introduction course the attendees will receive a certificate of completion.


Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF for Light and Ordinary Hazards (OH1)
  • AquaMist ULF for Industrial Fryer Protection (FM approved system)
  • AquaMist ULF for Data Center Protection (FM approved system)
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center)


Course Information

  • Duration: 8 hours
  • Availability: Europe 
  • Target Audience: Public
  • Certification: Certificate of Completion

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist Systems Certification training


Certification Training for AquaMist low pressure systems. 

During two days of comprehensive training, attendees will gain an understanding of the AquaMist ULF low pressure water mist technology protecting Machinery Spaces, Buildings and Data Centers. A general overview on the fire tests done for the FM approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice including information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details. 
The course will end with an exam and attendees will receive a certificate of training.

 

Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF Machinery Spaces system for total flooding systems according FM, design.
  • AquMist ULF for Data Cednter Protection (FM approved systems), dessign
  • AquaMist ULF for Light and Ordinary Hazards (OH1), design
  • AquaMist System hardware
  • Exam

Course Information

  • Duration:2 days
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

Introduction to Water Mist Systems

Introduction to Water Mist Systems

In this class we will provide an overview of our AquaMist fire protection solutions for different applications. We do show the difference between traditional sprinkler systems and Watermist as well as a live demonstration on spray patterns.

Course Information

  • Duration: 4 hours
  • Availability: Singapore, Dubai, Bangalore (India)
  • Target Audience: Open enrollment
  • Certification: Certificate of Training
To enroll in this class or find out more information, email for Singapore / Bangalore training-apac@tycofp.com and Dubai training-ME@tyco-bspd.com.

For 2019 schedule on this course and other open enrollments in the region please visit: Training Schedule 2019 - AP/ME

Europe / Africa

AquaMist for Building Protection


Certification Training for AquaMist low pressure systems for Building protecting
 

The objective of this certification training session is an introduction on the AquaMist ULF low pressure watermist technology as a Performance-based Design System for protection of Light and Ordinary Hazard (OH1) occupancies. A general overview on the fire tests done for the FM approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details.

The course will end with an exam and attendees will receive a certificate of training. 

Building Protection picture 1

Highlights

  • Low Pressure Water Mist systems introduction - AquaMist 
  • AquaMist ULF for Light and Ordinary Hazards (OH1), design.
  • AquaMist System hardware.
  • Introduction to AquaMist ULF for Industrial Fryer Protection (FM approved systems)
  • Introduction to AquaMist ULF for Data Center Protection (FM approved systems)
  • Demonstration of low pressure water mist nozzle discharges (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist for Machinery Spaces


Certification Training for AquaMist systems for protecting Machinery Spaces
  

The objective of this certification training session is an introduction to the AquaMist ULF low pressure water mist technology for protection of Machinery Spaces according FM and IMO regulations, also AquaMist FOG high pressure cylinder based FM approved systems for protection of Machinery Spaces according FM will be covered. A general overview on the fire tests done for the FM/IMO approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice  including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details. 

The course will end with an exam and attendees will receive a certificate of training.

Machinery Spaces picture 1
Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF Machinery Spaces system design for total flooding systems according FM, local application acc. IMO.
  • AquaMist FOG Machinery Spaces system design for total flooding systems according FM.
  • AquaMist System Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam

Course Information

  • Duration: 8 hours
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist low pressure for Data Center


Certification Training on AquaMist ULF systems for protecting large Data Halls in Datacenters 
  

The objective of this certification training session is an introduction on the AquaMist ULF low pressure water mist technology for protecting large Data Halls with computer racks in Data Centers.  A general overview on the fire tests done for the FM approved system, nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details.

The course will end with an exam and attendees will receive a certificate of training.

Datacenter picture 1

Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF for Data Center protection, system design.
  • AquaMist ULF System hardware.
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam

Course Information

  • Duration: 8 hours
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist low pressure for Industrial Fryers


Certification Training for AquaMist ULF systems for protecting Industrial Fryers
  

The objective of this certification training session is an introduction on the AquaMist ULF low pressure water mist technology for protecting large Industrial Fryers in the food industry. A general overview on the fire tests done for the FM approved system, nozzles and components used with the system will be provided. Design criteria, applications and installation practice including hands-on information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details.
The course will end with an exam and attendees will receive a certificate of training.

Industrial Fryers picture 3
Highlights

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF IFP for Industrial Fryer protection, system design.
  • AquaMist ULF System hardware.
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center).
  • Exam


Course Information

  • Duration: 8 hours
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist low pressure solutions


Introduction training to AquaMist low pressure water mist solutions
   

The objective of this Introduction training session on AquaMist Solutions is to explain the control/suppression/extinguishing principles of low pressure water mist systems and broad range of different applications where to use low pressure water mist systems  based on fire protection standards as NFPA750 and CENTS14972. 

After attending this one day introduction course the attendees will receive a certificate of completion.

Aquamist logo CMYK

Highlights Low pressure solutions

  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF for Light and Ordinary Hazards (OH1)
  • AquaMist ULF for Industrial Fryer Protection (FM approved system)
  • AquaMist ULF for Data Center Protection (FM approved system)
  • Demonstration of low pressure water mist nozzle discharge (when hold in a TechXchange training center)


Course Information

  • Duration: 8 hours
  • Availability: Europe
  • Target Audience: Public
  • Certification: Certificate of Completion

To enroll in this class or find out more information, login to your account at the top of this page.

AquaMist Systems Certification training


Certification Training for AquaMist low pressure systems. 

During two days of comprehensive training, attendees will gain an understanding of the AquaMist ULF low pressure water mist technology protecting Machinery Spaces, Buildings and Data Centers. A general overview on the fire tests done for the FM approved nozzles and components used with the system will be provided. Design criteria, applications and installation practice including information on the Grinnell® G-Press™ Piping System and Watermist pump skid will be discussed in details. 
The course will end with an exam and attendees will receive a certificate of training.AquaMist Systems Certification 3 nozzles

Aquamist logo CMYK

 Highlights
  • Low Pressure Water Mist systems introduction - AquaMist
  • AquaMist ULF Machinery Spaces system for total flooding systems according FM, design.
  • AquMist ULF for Data Center Protection (FM approved systems), dessign
  • AquaMist ULF for Light and Ordinary Hazards (OH1), design
  • AquaMist System hardware
  • Exam

Course Information

  • Duration:2 days
  • Availability: Europe
  • Target Audience: Authorized Distributors Only
  • Certification: Certificate of Training

To enroll in this class or find out more information, login to your account at the top of this page.